Clinical evaluation of a "virtual" methodology for providing 6 degrees of freedom (6DOF) patient set-up corrections and comparison to corrections facilitated by a 6DOF robotic couch. A total of 55 weekly in-room image-guidance... more
Motivation-Image-guided percutaneous (through the skin) needle-based surgery has become part of routine clinical practice in performing procedures such as biopsies, injections and therapeutic implants. A novice physician typically... more
Surgical robotics is a domain where the robot has to interact with human beings in order to treat patients in a very constrained working environment; therefore dependability cannot be ignored. In this paper, we discuss some requirements... more
Advances in regenerative medicine are rapidly transforming healthcare. A cornerstone of regenerative medicine is the introduction of cells that were grown or manipulated in vitro. Key questions that arise after these cells are... more
We present the proof-of-concept prototype of a prostate biopsy robot to be used inside a conventional high-field MRI scanner. A three degree-offreedom (DOF) mechanical device translates and rotates inside the rectum and enters a needle... more
We present the concept and prototype of an image-guided robotic system for accurate and consistent placement of percutaneous needles in soft tissue targets under CT-guidance. The system is a promising embodiment of the Surgical CAD/CAM... more
Rationale and Objectives. The purpose of this study was to assess the work-in-progress prototype of an image-guided, robotic system for accurate and consistent placement of transperineal needles into the prostate with intraoperative image... more
Radiofrequency ablation (RFA) represents a convenient, minimally invasive, and cost-effective approach for the treatment of small liver cancers measuring less than 3 cm in diameter. Nonetheless, the existing RFA techniques encounter... more
Low-field magnetic resonance imaging (MRI) has recently been integrated with radiation therapy systems to provide image guidance for daily cancer radiation treatments. The main benefit of the low-field strength is minimal electron return... more
Purpose-In this study, protein-shell microspheres filled with a suspension of iron oxide nanoparticles in oil are demonstrated as multimodal contrast agents in magnetic resonance imaging (MRI), magnetomotive optical coherence tomography... more
Aim: To evaluate the safety and efficacy of uncooled TATO microwave ablation (MWA) for primary and metastatic liver cancer. Materials & methods: This was a retrospective study on percutaneous liver ablations performed with TATO MWA.... more
Background: Radiosurgery is defined as the use of high-dose ionizing radiation for precise and total destruction of a chosen target, avoiding concomitant or delayed harm to adjacent tissues. The three types of radiations include gamma... more
Purpose Currently, intraoperative ultrasound in brain tumor surgery is a rapidly propagating option in imaging technology. We examined the accuracy and resolution limits of different ultrasound probes and the influence of... more
the better coverage of the high dose CTV, while respecting the constraints of the critical OAR (brainstem, chiasma, optic nerves).
Although the use of image guidance surgery (IGS) is standard practice in developed countries, it has not been in use in Indian Otolaryngology ever since its clinical inception in 1994. Some clinically interesting applications, relevant... more
Objective. The purpose of this study was to assess the correlation between skin-to-epidural space depth, as measured on cervical magnetic resonance imaging (MRI), and actual needle depth, as measured by Tuohy needle markings during... more
Objective. The purpose of this study was to assess the correlation between skin-to-epidural space depth, as measured on cervical magnetic resonance imaging (MRI), and actual needle depth, as measured by Tuohy needle markings during... more
An epidural steroid injection may help alleviate radicular pain felt in either your arm or leg resulting from pressure and irritation on one of the nerves. Once positioned appropriately by your doctor, a fluoroscope (X-ray guided machine)... more
Purpose: To assess the optimal planning target volume (PTV) margins for stereotactic body radiotherapy (SBRT) of prostate cancer based on inter-and intra-fractional prostate motion determined from daily image guidance. Methods and... more
The aim of the current study is to present our experience in lumbar spine interventional procedures performed with a newly developed multimodal echo-navigator (EcoNav) and to evaluate short-term clinical outcomes of a series of patients... more
Objectives: Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the... more
Purpose-To assess the accuracy of kV cone-beam CT (CBCT) based setup corrections as compared to orthogonal MV portal image-based corrections for patients undergoing external-beam radiotherapy of the prostate. Method and Materials-Daily... more
Image guidance is a technique that often uses virtual reality to provide accurate localization and real-time surgical navigation. Combining image guidance with a biosensor based on Raman spectroscopy, a powerful laser-based analysis... more
To investigate the impact of daily image-guided radiation therapy (IGRT) technique on clinical outcomes in patients with inoperable non-small cell lung cancer (NSCLC) treated with definitive chemoradiation therapy (CRT). We compared... more
The ability to determine the accuracy of the final prostate position within a determined action level threshold for image-guided proton therapy is unclear. Materials and Methods: Three thousand one hundred ten images for 20 consecutive... more
Awake Craniotomy with endoscopic support, guided by intraoperative ultrasound, Imeka Neuronavigator and MRI for excision of low-grade Astrocytoma in Sharab Hospital. Case Report. Fontes C1; Sama Y2; Sulayman S 3; BaldehS 4; Ceesay A5;... more
Intraoperative MRI has recently entered the operating room as a new imaging modality. Customized visualization systems might furrher facilitate the use of this imaging technology. A visualization system for use in the interventional MTU... more
Synchrotron microbeam radiation therapy is a promising pre-clinical radiation treatment modality; however, it comes with many technical challenges. This study describes the image guidance protocol used for Australia’s first long-term... more
This paper aims to describe a case of an immunocompetent 60-year-old patient presenting a subarachnoid hemorrhage in the absence of aneurysmal disease. Initial evaluation pointed to vasculitis of the central nervous system secondary to... more
We present the proof-of-concept prototype of a prostate biopsy robot to be used inside a conventional high-field MRI scanner. A three degree-offreedom (DOF) mechanical device translates and rotates inside the rectum and enters a needle... more
Background-Cardiac perforation during atrial septal puncture (ASP) might be avoided by improved image guidance. X-ray fluoroscopy (XRF), which guides ASP, visualizes tissue poorly and does not convey depth information. Ultrasound is... more
Purpose In the surgical treatment for lower-leg intraarticular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard... more
Pre-curved needles are used in a variety of medical applications for both passive and active control of instrument position. In one application, the deployment of a pre-curved stylet from a concentric outer cannula can be used to achieve... more
Background Commercially available systems for computer-assisted pedicle screw placement are prohibitively expensive, even in advanced countries. The advantage of the great accuracy of computer-assisted systems for pedicle screw insertion... more
Bilgisayar teknolojisindeki gelișmelere paralel olarak görüntüleme yöntemlerinde de gelișmeler olmuș, tüm bunlar radyoterapi planlama sistemlerinde daha kompleks planlamalar yapmaya olanak sağlamıștır. Bu gelișmeler üç-boyutlu konformal... more
Precise patient positioning is critical due to the large fractional doses and small treatment margins employed for thoracic stereotactic body radiation therapy (SBRT). The goals of this study were to evaluate the following: (1) the... more
Aims and background. The present study evaluated toxicity, local control, and survival in patients with relapsed high-grade glioma after surgery and external beam radiation therapy and treated with re-operation and GliaSite brachytherapy.... more
Demands for mechanical accuracy of medical linear accelerators are increased due to the stereotactic and modulated rotational treatments. Mechanical inaccuracies affect the size and shape of the mechanical and radiation isocenters. In... more
Demands for mechanical accuracy of medical linear accelerators are increased due to the stereotactic and modulated rotational treatments. Mechanical inaccuracies affect the size and shape of the mechanical and radiation isocenters. In... more
The advent of advanced technologies has brought unprecedented precision and efficacy to neurosurgical procedures for brain tumor resection. Despite the remarkable progress, disparities in tech- nology access across different nations... more
Fast and accurate proton computed tomography image reconstruction for applications in proton therapy
Proton computed tomography has been suggested as a means for maximizing the potential benefits of proton radiation therapy. By measuring individual proton energy losses after traversing an object and predicting paths of maximum likelihood... more
We evaluated the overall setup accuracy for the On-Board Imager (OBI, Varian Medical Systems Inc., Palo Alto, CA, USA), with attention to the laser, the gantry, and operator performance. We let experienced technicians place the marker... more
The ImagingRing, a novel cone-beam computed tomography (CBCT) imaging device with independently rotatable x-ray source and flat-panel detector arms, allows for planar and CBCT acquisitions of arbitrary regions inside the device’s... more
In external beam radiotherapy of prostate cancer, the consideration of various systematic error types leads to wide treatment margins compromising normal tissue tolerance. We investigated if systematic set-up errors can be reduced by a... more
Schedule overview Thursday, 2 nd June 2016 Conference room-PAN, 17/19 Wieniawskiego Street 11.00-16.30 Workshop I: Brachytherapy in clinical practice (Applied methodology and protocols)-Elekta 12.30-12.45 CT planning in HDR brachytherapy... more
Background: Cancer is one of the most dreadful diseases all over the world that can cause death. Cancer could be treated with different methods such as surgery, chemotherapy or radiotherapy. Methodology: In this review study, various... more