Towards Bio-Impedance based labs: A review
2015, 2015 Conference on Design of Circuits and Integrated Systems (DCIS)
https://doi.org/10.17265/2328-2223/2016.03.002Abstract
In this article, some of the main contributions to BI (Bio-Impedance) parameter-based systems for medical, biological and industrial fields, oriented to develop micro laboratory systems are summarized. These small systems are enabled by the development of new measurement techniques and systems (labs), based on the impedance as biomarker. The electrical properties of the life mater allow the straightforward, low cost and usually non-invasive measurement methods to define its status or value, with the possibility to know its time evolution. This work proposes a review of bio-impedance based methods being employed to develop new LoC (Lab-on-a-Chips) systems, and some open problems identified as main research challenges, such as, the accuracy limits of measurements techniques, the role of the microelectrode-biological impedance modeling in measurements and system portability specifications demanded for many applications.
References (66)
- Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., and Manz, A. 1993. "Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip." Science 261 (5123): 895-7.
- Oosterbroek, R., and Berg, A. 2003. Lab-on-a-Chip.
- Miniaturised Systems for (Bio) Chemical Analysis and Synthesis. Elsevier B.V.
- Ghallab, Y. H., and Ismail, Y. 2014. "CMOS Based Lab-on-a-Chip: Applications, Challenges and Future Trends" IEEE Circuits Syst. Mag. 14 (2): 27-47.
- Romani, A., Manaresi, N., Marzocchi, L., Medoro, G., Leonardi, A., Altomare, L., Tartagni, M., and Guerrieri, R. 2004. "Capacitive Sensor Array for Localization of Bioparticles in CMOS Lab-on-a-chip." 2004 IEEE International Solid-State Circuits Conference (IEEE Cat. No.04CH37519), 4-11.
- Medoro, G., Manaresi, N., Leonardi, A., Altomare, L., Tartagni, M., and Guerrieri, R. 2003. "A Lab-on-a-chip for Cell Detection and Manipulation." IEEE Sens. J. 3 (3): 317-25.
- Manaresi, N., Romani, A., Medoro, G., Altomare, L., Leonardi, A., Tartagni, M., and Guerrieri, R. 2003. "A CMOS Chip for Individual Cell Manipulation and Detection." 2003 IEEE International Solid-State Circuits Conference, Digest of Technical Papers ISSCC., Vol. 1, 192-487.
- Yúfera, A., Gallego, E., and Molina, J. 2011. "ImagCell: A Computer Tool for Cell Culture Image Processing Applications in Bioimpedance Measurements." Advances in Experimental Medicine and Biology 696: 733-40.
- Piacentini, N., Demarchi, D., Civera, P., and Knaflitz, M. 2008. "MEMS-Based Blood Cell Counting System." Electronics, Circuits and Systems, 2008. ICECS 2008. 15th IEEE International Conference, 198-201.
- Majer, L., Stopjakov, V., and Vavrinsk, E. 2009. "Wireless Measurement System for Non-Invasive Biomedical Monitoring of Psycho-Physiological Processes." J. Electr. Eng. 60 (2): 57-68.
- Nelson, N., Sander, D., Dandin, M., Prakash, S. B., Sarje, A., and Abshire, P. 2009. "Handheld Fluorometers for Lab-on-a-chip Applications." IEEE Trans. Biomed. Circuits Syst. 3 (2): 97-107.
- Holzinger, A. 2014. Biomedical Informatics: Discovering Knowledge in Big Data. Cham: Springer International Publishing.
- Satake D., Ebi, H., Oku, N., Matsuda, K., Takao H., et al. 2002. "A Sensor for Blood Cell Counter Using MEMS Technology." Sensors Actuators, B Chem. 83 (1-3): 77-81.
- Yúfera, A., Rueda, A., Muñoz, J. M., Doldán, R., Leger, G., and Rodríguez-Villegas, E. O. 2005. "A Tissue Impedance Measurement Chip for Myocardial Ischemia Detection." IEEE Trans. Circuits Syst. I Regul. Pap. 52 (12): 2620-8.
- Yufera, A., and Rueda, A. 2009. "A CMOS Bio-Impedance Measurement System." Advances in Experimental Medicine and Biology 696: 252-7.
- Radke, S. M., and Alocilja, E. C. 2004. "Design and Fabrication of a Microimpedance Biosensor for Bacterial Detection." IEEE Sens. J. 4 (4): 434-40.
- Gensler, H., Sheybani, R., Li, P. Y., Lo, R., Zhu, S., Yong, K. T., Roy, I., et al. 2010. "Implantable MEMS Drug Delivery Device for Cancer Radiation Reduction." Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), 23-6.
- Chung, W. Y., Bhardwaj, S., Purwar, A., Lee, D. S., and Myllylae, R. 2007. "A Fusion Health Monitoring Using ECG and Accelerometer Sensors for Elderly Persons At Home." Annual International Conference of the IEEE Engineering in Medicine and Biology Proceedings, 3818-21.
- Scott, J., and Single, P. 2013. "Compact Nonlinear Model of an Implantable Electrode Array for Spinal Cord Stimulation (SCS)." IEEE Trans. Biomed. Circuits Syst. 8 (3): 382-90.
- Lajunen, T., Viitala, L., Kontturi, L. S., Laaksonen, T., Liang, H., Vuorimaa-Laukkanen, E., Viitala, T., Le Guèvel, X., Yliperttula, M., Murtomäki, L., and Urtti, A. 2015. "Light Induced Cytosolic Drug Delivery from Liposomes with Gold Nanoparticles." J. Control. Release 203: 85-98.
- Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., and Parviz, B. A. 2011. "A Contact Lens with Embedded Sensor for Monitoring Tear Glucose Level." Biosens. Bioelectron. 26 (7): 3290-6.
- Schwan, H. P. 1994. "Electrical Propertis of Tissues and Cell Suspensions: Mechanisms and Models." Engineering in Medicine and Biology Society: 70-1.
- Mellert, F., Winkler, K., Schneider, C., Dudykevych, T., et al. 2011. "Detection of (Reversible) Myocardial Ischemic Injury by Means of Electrical Bioimpedance." IEEE Trans. Biomed. Eng. 58 (6): 1511-8.
- Mercanzini, A., Colin, P., Bensadoun, J.-C., Bertsch, A., and Renaud, P. 2009. "In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays." IEEE Trans. Biomed. Eng. 56 (7): 1909-18.
- Huang, W. H., Chui, C. K., Teoh, S. H., and Chang, S. K. Y. 2012. "A Multiscale Model for Bioimpedance Dispersion of Liver Tissue." IEEE Trans. Biomed. Eng. 59 (6): 1593-7.
- Daza, P., Olmo, A., Cañete, D., and Yúfera, A. 2013. "Monitoring Living Cell Assays with Bio-impedance Sensors." Sensors Actuators B Chem. 176: 605-10.
- Borkholder, D. 1998. "Cell Based Biosensors Using Microelectrodes." Stanford University.
- Alexander, F. A., Price, D. T., and Bhansali, S. 2013. "From Cellular Cultures to Cellular Spheroids: Is Impedance Spectroscopy a Viable Tool for Monitoring Multicellular Spheroid (MCS) Drug Models?" IEEE Rev. Biomed. Eng. 6: 63-76.
- Huang, X., Nguyen, D., Greve, D. W., and Domach, M. M. 2004. "Simulation of Microelectrode Impedance Changes Due to Cell Growth." IEEE Sens. J. 4 (5): 576-83.
- Huertas, G., Maldonado, A., Yufera, A., Rueda, A., and Huertas, J. L. 2015. "The Bio-oscillator: A Circuit for Cell-Culture Assays." IEEE Trans. Circuits Syst. II Express Briefs 62 (2): 164-8.
- Giaever, I., and Keese, C. R. 1986. "Use of Electric Fields to Monitor the Dynamical Aspect of Cell Behavior in Tissue Culture." IEEE Trans. Biomed. Eng. 33 (2): 242-7.
- Das, D., Kamil, F. A., Agrawal, S., Biswas, K., and Das, S. 2014. "Fragmental Frequency Analysis Method to Estimate Electrical Cell Parameters From Bioimpedance Study." IEEE Trans. Instrum. Meas. 63 (8): 1991-2000.
- Guo, F. Q., Wei, W., Wei, D., Fan, Zh., Sinclair, A. J., and Chatwin, C. R. 2012. "Bioimpedance Analysis for the Characterization of Breast Cancer Cells in Suspension." IEEE Trans. Biomed. Eng. 59 (8): 2321-9.
- Aberg, P., Nicander, I., Hansson, J., Geladi, P., Holmgren, U., and Ollmar, S. 2004. "Skin Cancer Identification Using Multifrequency Electrical Impedance-A Potential Screening Tool." IEEE Trans. Biomed. Eng. 51 (12): 2097-102.
- Giaever, I., and Keese, C. R. 1991. "Micromotion of Mammalian Cells Measured Electrically." Proc. Natl. Acad. Sci. 88 (17): 7896-900.
- Linderholm, P., Braschler, T., Vannod, J., Barrandon, Y., Brouard, M., and Renaud, P. 2006. "Two-dimensional Impedance Imaging of cell Migration and Epithelial Stratification." Lab Chip 6 (9): 1155-62.
- Beach, R. D., Conlan, R. W., Godwin, M. C., and Moussy, F. 2005. "Towards a Miniature Implantable In Vivo Telemetry Monitoring System Dynamically Configurable as a Potentiostat or Galvanostat for Two- and Three-Electrode Biosensors." IEEE Trans. Instrum. Meas. 54 (1): 61-72.
- Manickam, A., Chevalier, A., McDermott, M., Ellington, A. D., and Hassibi, A. 2010. "A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array." IEEE Trans. Biomed. Circuits Syst. 4 (6): 379-90.
- Hassibi, A., and Lee, T. H. 2006. "A Programmable 0.18-µm CMOS Electrochemical Sensor Microarray for Biomolecular Detection." IEEE Sens. J. 6 (6): 1380-8.
- Holder, D. 2005. Electrical Impedance Tomography: Methods, History and Applications. IOP.
- Ausin, J. L., Ramos, J., Torelli, G., and Duque-Carillo, J. F. 2014. "Live Demonstration: A Wireless Multichannel Bioimpedance Spectrometer for Patient Monitoring." 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings, 176.
- Yan, L., Pettine, J., Mitra, S., Kim, S., Jee, D.-W., Kim, H., Osawa, M., Harada, Y., Tamiya, K., Van Hoof, C., and Yazicioglu, R. F. 2013. "A 13 μA Analog Signal Processing IC for Accurate Recognition of Multiple Intra-cardiac Signals." IEEE Trans. Biomed. Circuits Syst. 7 (6): 785-95.
- Taji, B., Shirmohammadi, S., Groza, V., and Batkin, I. 2014. "Impact of Skin-Electrode Interface on Electrocardiogram Measurements Using Conductive Textile Electrodes." IEEE Trans. Instrum. Meas. 63 (6): 1412-22.
- Guermandi, M., Cardu, R., Franchi Scarselli, E., and Guerrieri, R. 2015. "Active Electrode IC for EEG and Electrical Impedance Tomography with Continuous Monitoring of Contact Impedance." IEEE Trans. Biomed. Circuits Syst. 9 (1):21-33.
- Martinsen, Ø. G., Nordbotten, B., Grimnes, S., Fossan, H., and Eilevstjønn, J. 2014. "Bioimpedance-Based Respiration Monitoring with a Defibrillator." IEEE Trans. Biomed. Eng. 61 (6): 1858-62.
- Lee, W., and Cho, S. 2015. "Integrated All Electrical Pulse Wave Velocity and Respiration Sensors Using Bio-Impedance." IEEE J. Solid-State Circuits 50 (3): 776-85.
- Ha, S., Kim, C., Chi, Y. M., Akinin, A., Maier, C., Ueno, A., and Cauwenberghs, G. 2014. "Integrated Circuits and Electrode Interfaces for Noninvasive Physiological Monitoring." IEEE Trans. Biomed. Eng. 61 (5): 1522-37.
- Grimnes, S., and Martinsen, O. 2008. Bioimpedance and Bioelectricity Basics. Academic Press.
- Ackmann, J. J. 1993. "Complex Bioelectric Impedance Measurement System for the Frequency Range From 5 Hz to 1 MHz." Ann. Biomed. Eng. 21 (2): 135-46.
- Pallás-Areny, R., and Webster, J. G. 1993. "Bioelectric Impedance Measurements Using Synchronous Sampling." IEEE Trans. Biomed. Eng. 40 (8): 824-9.
- Robinson, D. A. 1968. "The Electrical Properties of Metal Microelectrodes." Proc. IEEE 56 (6): 1065-71.
- Schwan, H. P. 1963. Electrophysiological Methods. Elsevier.
- Simpson, R. W., Berberian, J. G., and Schwan, H. P. 1980. "Nonlinear AC and DC Polarization of Platinum Electrodes." IEEE Trans. Biomed. Eng. 27 (3): 166-71.
- Schwan, H. P. 1992. "Linear and Nonlinear Electrode Polarization and Biological Materials." Ann. Biomed. Eng. 20 (3): 269-88.
- Bockris, J. O., and Reddy, A. K. N. 1970. Modern Electrochemistry. Plenum Press.
- Schwan, H. P. 1968. "Electrode Polarization Impedance and Measurements in Biological Materials." Ann. N. Y. Acad. Sci. 148 (1): 191-209.
- COMSOL. "The Use of the Conductive Media DC Application Mode for Time-Harmonic Problems, Solution."
- Li, N., Xu, H., Zhou, Z., Xin, J., Sun, Z., and Xu, X. 2013. "Reconfigurable Bioimpedance Emulation System for Electrical Impedance Tomography System Validation." IEEE Trans. Biomed. Circuits Syst. 7 (4): 460-8.
- Ramos, J., Ausin, J. L., Torelli, G., and uque-Carrillo, J. F. 2009. "A Wireless Sensor Network for Fat and Hydration Monitoring by Bioimpedance Analysis." In Proceedings of the 6th International Workshop on Wearable, Micro, and Nano Technologies for Personalized Health, 49-52.
- Baeg, J. C., Wi, H., Oh, T. I., McEwan, A. L., and Woo, E. J. 2013. "An Amplitude-to-time Conversion Technique Suitable for Multichannel Data Acquisition and Bioimpedance Imaging." IEEE Trans. Biomed. Circuits Syst. 7 (3): 349-54.
- Yúfera, A., and Rueda, A. 2010. "Design of a CMOS Closed-loop System with Applications to Bio-impedance measurements." Microelectronics J. 41 (4): 231-9.
- Bragós, R., Sarro, E., Fontova, A., Soley, A., Cairó, J., Bayés-Genís, A., and Rosell, J. 2006. "Four Versus Two-electrode Measurement Strategies for Cell Growing and Differentiation Monitoring Using Electrical Impedance Spectroscopy." Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. IEEE Eng. Med. Biol. Soc. Annu. Conf. 1: 2106-9.
- Pradhan, R., Mandal, M., Mitra, A., and Das, S. 2014. "Assessing Cytotoxic Effect of ZD6474 on MDA-MB-468 Cells Using Cell-Based Sensor." IEEE Sens. J. 14 (5): 1476-81.
- Kassanos, P., Constantinou, L., Triantis, I. F., and Demosthenous, A. 2014. "An Integrated Analog Readout for Multi-Frequency Bioimpedance
- Measurements." IEEE Sens. J. 14 (8): 2792-800.
- Kubendran, R., Lee, S., Mitra, S., and Yazicioglu, R. F. 2014. "Error Correction Algorithm for High Accuracy Bio-impedance Measurement in Wearable Healthcare Applications." IEEE Trans. Biomed. Circuits Syst. 8 (2): 196-205.