As mechanical stability of radiation therapy treatment devices has gone beyond sub-millimeter levels, there is a rising demand for simple yet highly accurate measurement techniques to support the routine quality control of these devices.... more
As mechanical stability of radiation therapy treatment devices has gone beyond sub-millimeter levels, there is a rising demand for simple yet highly accurate measurement techniques to support the routine quality control of these devices. A combination of using high-resolution radiosensitive film and computeraided analysis could provide an answer. One generally known technique is the acquisition of star shot films to determine the mechanical stability of rotations of gantries and the therapeutic beam. With computer-aided analysis, mechanical performance can be quantified as a radiation isocenter radius size. In this work, computer-aided analysis of star shot film is further refined by applying an analytical solution for the smallest intersecting circle problem, in contrast to the gradient optimization approaches used until today. An algorithm is presented and subjected to a performance test using two different types of radiosensitive film, the Kodak EDR2 radiographic film and the ISP EBT2 radiochromic film. Artificial star shots with a priori known radiation isocenter size are used to determine the systematic errors introduced by the digitization of the film and the computer analysis. The estimated uncertainty on the isocenter size measurement with the presented technique was 0.04 mm (2σ ) and 0.06 mm (2σ ) for radiographic and radiochromic films, respectively. As an application of the technique, a study was conducted to compare the mechanical stability of O-ring gantry systems with C-arm-based gantries. In total ten systems of five different institutions were included in this study and star shots were acquired for gantry, collimator, ring, couch rotations and gantry wobble. It was not possible to draw general conclusions about differences in mechanical performance between O-ring and C-arm gantry systems, mainly due to differences in the beam-MLC alignment procedure accuracy. Nevertheless, the best performing O-ring system in this study, a BrainLab/MHI Vero system, and the best performing C-arm system, a Varian Truebeam system, showed comparable mechanical performance: gantry isocenter radius of 0.12 and 0.09 mm, respectively, ring/couch rotation of below 0.10 mm for both systems and a wobble of 0.06 and 0.18 mm, respectively. The methodology described in this work can be used to monitor mechanical performance constancy of high-accuracy treatment devices, with means available in a clinical radiation therapy environment.
Background and purpose: For dynamic tracking of moving tumors, robust intra-fraction verification was required, to assure that tumor motion was properly managed during the course of radiotherapy. A dual-modality verification system,... more
Background and purpose: For dynamic tracking of moving tumors, robust intra-fraction verification was required, to assure that tumor motion was properly managed during the course of radiotherapy. A dual-modality verification system, consisting of an on-board orthogonal kV and planar MV imaging device, was validated and applied retrospectively to patient data. Methods and materials: Real-time tumor tracking (RTTT) was managed by applying PAN and TILT angular corrections to the therapeutic beam using a gimbaled linac. In this study, orthogonal X-ray imaging and MV EPID fluoroscopy was acquired simultaneously. The tracking beam position was derived from respectively real-time gimbals log files and the detected field outline on EPID. For both imaging modalities, the moving target was localized by detection of an implanted fiducial. The dual-modality tracking verification was validated against a high-precision optical camera in phantom experiments and applied to clinical tracking data from a liver and two lung cancer patients. Results: Both verification modalities showed a high accuracy (<0.3 mm) during validation on phantom. Marker detection on EPID was influenced by low image contrast. For the clinical cases, gimbaled tracking showed a 90th percentile error (E90) of 3.45 (liver), 2.44 (lung A) and 3.40 mm (lung B) based on EPID fluoroscopy and good agreement with XR-log file data by an E90 of 3.13, 1.92 and 3.33 mm, respectively, during beam on. Conclusion: Dual-modality verification was successfully implemented, offering the possibility of detailed reporting on RTTT performance.
- by Dirk Verellen and +2
- •
- Particle Accelerators
Purpose: To have an initial assessment of the Vero Dynamic Tracking workflow in clinical circumstances and quantify the performance of the tracking system, a simulation study was set up on 5 lung and liver patients. Methods and materials:... more
Purpose: To have an initial assessment of the Vero Dynamic Tracking workflow in clinical circumstances and quantify the performance of the tracking system, a simulation study was set up on 5 lung and liver patients. Methods and materials: The preparatory steps of a tumor tracking treatment, based on fiducial markers implanted in the tumor, were executed allowing pursuit of the tumor with the gimbaled linac and monitoring X-rays acquisition, however, without activating the 6 MV beam. Data were acquired on workflow time-efficiency, tracking accuracy and imaging exposure. Results: The average time between the patient entering the treatment room and the first treatment field was about 9 min. The time for building the correlation model was 3.2 min. Tracking errors of 0.55 and 0.95 mm (1r) were observed in PAN/TILT direction and a 2D range of 3.08 mm. A skin dose was determined of 0.08 mGy/image, with a source-to-skin distance of 900 mm and kV exposure of 1 mAs. On average 1.8 mGy/min kV skin dose was observed for 1 Hz monitoring. Conclusion: The Vero tracking solution proved to be fully functional and showed performance comparable with other real-time tracking systems.
Because frame rates on current clinical available electronic portal imaging devices (EPID's) are limited to 7.5 Hz, a new commercially available PerkinElmer EPID (XRD 1642 AP19) with a maximum frame rate of 30 Hz and a new... more
Because frame rates on current clinical available electronic portal imaging devices (EPID's) are limited to 7.5 Hz, a new commercially available PerkinElmer EPID (XRD 1642 AP19) with a maximum frame rate of 30 Hz and a new scintillator (Kyokko PI200) with improved sensitivity (light output) for megavolt (MV) irradiation was evaluated. In this work, the influence of MV pulse artifacts and pulsing artifact suppression techniques on fiducial marker and marker-less detection of a lung lesion was investigated, because target localization is an important component of uncertainty in geometrical verification of real-time tumor tracking. Visicoil™ markers with a diameter of 0.05 and 0.075 cm were used for MV marker tracking with a frame rate of, respectively, 7.5, 15, and 30 Hz. A 30 Hz readout of the detector was obtained by a 2 × 2 pixel binning, reducing spatial resolution. Static marker detection was conducted in function of increasing phantom thickness. Additionally, marker-less tra...
- by Kenneth Poels and +1
- •
- Algorithms, Biomedical Engineering
The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery... more
The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation...
This study aimed to compare procedures for dynamic tumour tracking (DTT) using a gimbal-mounted linac between centres in Japan (KU-IBRI) and Belgium (UZB), to quantify tracking error (TE), and to estimate tumour-fiducial uncertainties and... more
This study aimed to compare procedures for dynamic tumour tracking (DTT) using a gimbal-mounted linac between centres in Japan (KU-IBRI) and Belgium (UZB), to quantify tracking error (TE), and to estimate tumour-fiducial uncertainties and PTV margins. Twenty-two patients were evaluated. TE was divided into components originating from the patient, fraction, segment, and residuals. KU-IBRI applied DTT to lung cancer, while UZB treated both the lung and liver. Patients from UZB were younger and had a higher body mass index. DTT procedures differed in the use of body fixation, correction for set-up error, type of fiducial markers, and goodness of fit of correlation model. TE was larger at UZB in the intra-fraction components, whereas the tumour-fiducial uncertainties were estimated to be larger at KU-IBRI. These results ultimately led to similar PTV margins at both centres (2.1, 4.2, and 2.6mm for KU-IBRI; 2.4, 3.6, and 2.0mm for UZB in LR, AP, and SI, respectively, for 99% coverage of ...
- by Dirk Verellen and +1
- •
To report on the first clinical application of a real-time tumor tracking (RTTT) solution based on the Vero SBRT gimbaled linac system for treatment of moving tumors. A first group of 10 SBRT patients diagnosed with NSCLC or... more
To report on the first clinical application of a real-time tumor tracking (RTTT) solution based on the Vero SBRT gimbaled linac system for treatment of moving tumors. A first group of 10 SBRT patients diagnosed with NSCLC or oligometastatic disease in lung or liver was treated with the RTTT technique. The PTV volumes and OAR exposure were benchmarked against the widely used ITV approach. Based on data acquired during execution of RTTT treatments, a first review was performed of the process. The 35% PTV volume reduction with RTTT of the studied single lesions SBRT irradiations of small target volumes is expected to result in a small (<1%) reduction of lung or liver NTCP. A GTV-PTV margin of 5.0mm was applied for treatment planning of RTTT. From patient data on residual geometric uncertainties, a CTV-PTV margin of 3.2mm was calculated. Reduction of the GTV-PTV margin below 5.0mm without better understanding of biological definition of tumor boundaries was discouraged. Total treatme...
- by Kenneth Poels and +2
- •
- Reproducibility of Results
For tumor tracking, a correlation model is used to estimate internal tumor position based on external surrogate motion. When patients experience an internal/external surrogate drift, an update of the correlation model is required to... more
For tumor tracking, a correlation model is used to estimate internal tumor position based on external surrogate motion. When patients experience an internal/external surrogate drift, an update of the correlation model is required to continue tumor tracking. In this study, the accuracy of the internal tumor position estimation for both the clinical available update at discrete points in time (rebuild) and an in-house developed non-clinical online update approach was investigated. A dynamic phantom with superimposed baseline drifts and 14 SBRT patients, treated with real-time tumor tracking (RTTT) on the Vero system, were retrospectively simulated for three update scenarios, respectively no update, clinical rebuild and 0.5 Hz automated online update of the correlation model. By comparing the target positions based on 0.5 Hz verification X-ray images with the estimated internal tumor positions regarding all three update scenarios, 95th percentile modeling errors (ME95), incidences of f...
- by Kenneth Poels and +2
- •
- Reproducibility of Results
Background: Acquired resistance to tyrosine kinase inhibitors (TKIs) in gastrointestinal stromal tumours (GISTs) is most commonly caused by secondary KIT or PDGFRA mutations. In this study we characterize a newly established GIST... more
Background: Acquired resistance to tyrosine kinase inhibitors (TKIs) in gastrointestinal stromal tumours (GISTs) is most commonly caused by secondary KIT or PDGFRA mutations. In this study we characterize a newly established GIST xenograft model, UZLX-GIST9, and evaluate the in vivo response of the model to standard TKIs (imatinib, sunitinib, and regorafenib). Methods: Tumour fragments from a metastatic lesion of a GIST patient clinically progressing after treatment with imatinib, sunitinib and regorafenib were engrafted in a nude, immunodeficient mouse. Upon sequential passaging from mouse to mouse, tumour fragments were collected for histopathological and molecular characterization. The sensitivity of the model to treatment with TKIs was evaluated in 28 mice [passage 2 (n = 8), passage 4 (n = 20), 41 tumours]. Mice were grouped as follows: control (untreated), imatinib (50 mg/kg/BID), imatinib (100 mg/kg/BID), sunitinib (40 mg/kg/QD), and regorafenib (30 mg/kg/QD). After three weeks of oral treatment, tumours were collected for subsequent analysis. The efficacy of treatment was assessed by tumour volume, histopathology and Western immunoblotting.