https://doi.org/10.1109/ISBI.2002.1029364Abstract
Cryo-electron microscopy is widely viewed as a uniquely powerful method for the study of membrane proteins and large macromolecular complexes-subjects that are viewed as extremely challenging or impossible to study using x-ray or NMR methods. Although the methodology of molecular microscopy has enormous potential, it is time consuming and labor intensive. Our group has done extensive work to automate image acquisition and processing for cryo-EM. In this paper we will provide an overview of our automated system, called Leginon, and present results where we used tobacco mosaic virus (TMV) as a proof of concept.
References (18)
- REFERENCES
- Bottcher, B., Wynne, S., and Crowther, R. (1997). "Determination of the fold of the core protein of hepatitis B virus by electron cryomicroscopy." Nature, 386(6620), 88-91.
- Carragher, B., Fellman, D., Kisseberth, N., Milligan, R. A., Potter, C. S., Pulokas, J., and Zhu., Y. (2001). "Automation for Cryo-TEM: From specimen grid to 3D map." Microscopy and Microanalysis, 7, 970-971.
- Carragher, B., Kisseberth, N., Kriegman, D., Milligan, R. A., Potter, C. S., Pulokas, J., and Reilein, A. (2000). "Leginon: An automated system for acquistion of images from vitreous ice specimens." Journal of Structural Biology, 132, 33-45.
- Carragher, B., Whittaker, M., and Milligan, R. A. (1996). "Helical Processing Using PHOELIX." Journal of Structural Biology, 116, 107-112.
- Conway, J., Wikoff, W., Cheng, N., Duda, R., Hendrix, R., Johnson, J., and Steven, A. (2001). "Virus maturation involving large subunit rotations and local refolding." Science, 292(5517), 744-8.
- Frank, J., and Agrawal, R. (2000). "A ratchet-like inter-subunit reorganization of the ribosome during translocation." Nature, 406(6793), 318-22.
- Henderson, R. (1995). "The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules." Quarterly Review of Biophysics, 28(2), 171-193.
- Koster, A. J., Ruijter, W. J. d., Bos, A. v. d., and Mast, K. D. v. d. (1989). "Autotuning of a TEM using minimum electron dose." Ultramicroscopy, 27, 251-272.
- Murata, K., Mitsuoka, K., Hirai, T., Walz, T., Agre, P., Heymann, J., Engel, A., and Fujiyoshi, Y. (2000). "Structural determinants of water permeation through aquaporin- 1." Nature, 407, 599-605.
- Nogales, E., Wolf, S., and Downing, K. (1998). "Structure of the alpha beta tubulin dimer by electron crystallography." Nature, 391(6663), 199-203.
- Potter, C. S., Chu, H., Frey, B., Green, C., Kisseberth, N., Madden, T. J., Miller, K. L., Nahrstedt, K., Pulokas, J., Reilein, A., Tcheng, D., Weber, D., and Carragher, B. (1999). "Leginon: A System for Fully Automated Acquisition of 1000 Micrographs a Day." Ultrmicroscopy, 77, 153-161.
- Ren, G., Reddy, V., Cheng, A., Melnyk, P., and Mitra, A. (2001). "Visualization of a water-selective pore by electron crystallography in vitreous ice." Proc Natl Acad Sci USA, 98(4), 1398-403.
- Saibil, H. R. (2000). "Macromolecular structure determination by cryo-electron microscopy." Acta Crystallographica Section D, D56, 1215-1222.
- VanLoock, M., Agrawal, R., Gabashvili, I., Qi, L., Frank, J., and Harvey, S. (2000). "Movement of the decoding region of the 16 S ribosomal RNA accompanies tRNA translocation." J Mol Biol., 304(4), 507-15.
- Zhang, P., Beatty, A., Milne, J. L. S., and Subramaniam, S. (2001). "Automated data collection with a Tecnai 12 electron microscope: applications for molecular imaging by cryomicroscopy." J. of Structural Biology, 135, 251-261.
- Zhou, Z. H., Dougherty, M., Jakana, J., He, J., Rixon, F. J., and Chiu, W. (2000). "Seeing the herpesvirus capsid at 8.5 A." Science, 288(5647), 877-880.
- Zhu, Y., Carragher, B., Kriegman, D. J., Milligan, R. A., and Potter, C. S. (2001). "Automated identification of filaments in cryoelectron microscopy images." Journal of Structural Biology, 135, 302-312.