Validation of SIMIND Monte Carlo for 99mTc and 177Lu
https://doi.org/10.21203/RS.3.RS-1756734/V1Abstract
Purpose : Monte Carlo (MC) simulation in Nuclear Medicine is a powerful tool for modelling many physical phenomena which are difficult to track or to measure directly. MC simulation in SPECT/CT imaging is particularly suitable for optimizing the quantification of activity in a patient, and, consequently, the absorbed dose to each organ. To do so, it is mandatory validate MC results with real data acquired with gamma camera. The aim of this study was the validation of SIMIND Monte Carlo code for modelling a Siemens Symbia Intevo Excel SPECT-CT gamma camera both for 99m Tc and 177 Lu. Methods : Phantom experiments using 99m Tc and 177 Lu have been performed with the purpose to measure spatial resolution, sensitivity and evaluate the calibration factor (CF) and recovery coefficients (RC) from acquired data. The geometries used for 2D planar imaging were (1) Petri dish and (2) capillary source while for 3D volumetric imaging were (3) a uniform filled cylinder phantom and (4) a Jaszczack...
References (18)
- Zaidi H. Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Med Phys. 1999;26:574-608.
- Liu S, Famcombe TH. Collimator-detector response compensation in quantitative SPECT reconstruction. In: 2007 IEEE Nuclear Science Symposium Conference Record: 27 October -3 November 2007; Hawaii. IEEE Nuclear Science; 2007. p. M19-327.
- Chun SY, Fessler JA, Dewaraja YK. Correction for Collimator-Detector Response in SPECT Using Point Spread Function Template. IEEE Trans Med Imaging. 2013;32:295-305.
- Willowson K, Bailey DL, Baldock C. Quantitative SPECT reconstruction using CT-derived corrections. Phys Med Biol. 2008;53:3099-3112.
- Pacilio M, Cassano B, Pellegrini R, Di Castro E, Zorzi A, De Vincentis G, et al. Gamma camera calibrations for the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases. Phys Medica. 2017;41:117-23.
- Zeintl J, Vija AH, Yahil A, Hornegger J, Kuwert T. Quantitative accuracy of clinical 99mTc SPECT/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction. J Nucl Med. 2010;51:921-8.
- Dong X, Saripan MI, Mahmud R, Mashohor S, Wang A. Characterization of SIEMENS Symbia T SPECT camera in Monte Carlo simulation environment. Pakistan Journal of Nuclear Medicine. 2019;8(1):18-26.
- Toossi MTb, Islamian PJ, Momennezhad M, Ljungberg M, Naseri SH. SIMIND Monte Carlo simulation of a single photon emission CT. Journal of Medical Physics. 2010;35(1):42-47.
- Ramonaheng K, van Staden JA, du Raan H. Validation of a Monte Carlo modelled gamma camera for Lutetium-177 imaging. Appl Radiat Isot. 2020;163:109200.
- Ejeh JE, van Staden JA, du Raan H. Validation of SIMIND Monte Carlo Simulation Software for Modelling a Siemens Symbia T SPECT Scintillation Camera. In: World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/1. Springer, Singapore. IUPESM; 2018. p. 573-576.
- Morphis M, van Staden JA, du Raan H, Ljungberg M. Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging. Heliyon. 2021;7(6):e07196.
- Ljungberg M. The SIMIND Monte Carlo program. In: M Ljungberg MAK S E Strand, editor. Monte Carlo calculations in nuclear medicine: Applications in diagnostic imaging. 2nd ed. Boca Raton: CRC Press; 2012. p. 111-128.
- Ljungberg M, Celler A, Konijnenberg MW, Eckerman KF, Dewaraja YK, Sjögreen-Gleisner K. MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT Applied for Dosimetry of Radiopharmaceutical Therapy. J Nucl Med. 2016;57:151-162.
- Merlin T, Stute S, Benoit D, Bert J, Carlier T, Comtat C, et al. CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction. Phys Med Bio. 2018;63:151-162.
- S R Cherry MEP J A Sorenson. Physics in Nuclear Medicine. Philadelphia: Elsevier Saunders; 2012.
- Frezza A, Desport C, Uribe C, Zhao W, Celler A, Després P, et al. Comprehensive SPECT/CT system characterization and calibration for 177 L u quantitative SPECT (QSPECT) with dead-time correction. Eur J Nucl Med Mol Imaging. 2020;7(10):1-22.
- Bé MM, Duchemin B, Lamé J, Morillon C, Piton F, Browne E, et al. Table de Radionucléides. vol. 1. DAMRI/LPRI BP 52, F-91193 Gif-sur-Yvette Cedex, France: Commissariat à l' Énergie Atomique; 1999.
- Uccelli L, Boschi A, Cittanti C, Martini P, Panareo S, Tonini E, et al. 90Y/177Lu-DOTATOC: From Preclinical Studies to Application in Humans. Pharmaceutics. 2021;13:1463.