Generator Protection Overcomes Current Transformer Limitations
2015
Abstract
Following industry standards to select current transformers (CTs) is the best way to avoid relay misoperations caused by CT saturation. Differences in the saturation characteristics of CTs used in generator differential protection can lead to uneven CT saturation during external events, such as transformer energization, which may result in the undesired operation of generator differential elements. In this paper, we review the challenges presented to generator differential protection elements in installations where a large spurious operating current appears during external events and examine adaptive protection elements that address these challenges.
References (12)
- IEEE Standard C37.110-2007, IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes.
- S. E. Zocholl, "Standard CT Accuracy Ratings in Metal-Clad Switchgear," proceedings of the 59th Annual Conference for Protective Relay Engineers, College Station, TX, April 2006.
- H. J. Altuve, N. Fischer, G. Benmouyal, and D. Finney, "Sizing Current Transformers for Line Protection Applications," proceedings of the 66th Annual Conference for Protective Relay Engineers, College Station, TX, April 2013.
- B. Kasztenny and D. Finney, "Generator Protection and CT Saturation Problems and Solutions," proceedings of the 58th Annual Conference for Protective Relay Engineers, College Station, TX, April 2005.
- R. E. Cordray, "Percentage-Differential Transformer Protection," Electrical Engineering, Vol. 50, Issue 5, May 1931, pp. 361-363.
- A. Guzmán, B. Qin, and C. Labuschagne, "Reliable Busbar Protection With Advanced Zone Selection," IEEE Transactions on Power Delivery, Vol. 20, Issue 2, April 2005, pp. 625-629.
- A. Guzmán, N. Fischer, and C. Labuschagne, "Improvements in Transformer Protection and Control," proceedings of the 62nd Annual Conference for Protective Relay Engineers, College Station, TX, March 2009.
- S. E. Zocholl, Analyzing and Applying Current Transformers. Schweitzer Engineering Laboratories, Inc., Pullman, WA, 2004.
- NERC Standard EOP-005-2 -System Restoration from Blackstart Resources. Available: http://www.nerc.com.
- E. O. Schweitzer, III, and D. Hou, "Filtering for Protective Relays," proceedings of the 19th Annual Western Protective Relay Conference, Spokane, WA, October 1992.
- G. Benmouyal and S. E. Zocholl, "The Impact of High Fault Current and CT Rating Limits on Overcurrent Protection," proceedings of the 29th Annual Western Protective Relay Conference, Spokane, WA, April 2002.
- R. Garret, W. C. Kotheimer, and S. E. Zocholl, "Computer Simulation of Current Transformers and Relays for Performance Analysis," proceedings of the 14th Annual Western Protective Relay Conference, Spokane, WA, October 1987.