Raja Ramanna Centre for Advanced Technology (RRCAT) has developed a 2K vertical Test Stand (VTS) ... more Raja Ramanna Centre for Advanced Technology (RRCAT) has developed a 2K vertical Test Stand (VTS) facility for characterization of Superconducting RF (SCRF) cavities, under Indian Institution Fermilab Collaboration (IIFC). The VTS facility comprises of a large size liquid helium (LHe) cryostat, cryogenic system, RF power supply, control and data acquisition system and radiation monitoring system. It will facilitate testing of superconducting cavities of different frequencies ranging from 325 MHz low beta to 650 MHz / 1.3 GHz medium and high beta cavities. The helium vessel has a capacity to store up to 2900 litres of liquid Helium. The cryostat is installed inside a vertical pit. It is equipped with facilities for supply of liquid nitrogen and liquid helium and vacuum system for pumping out helium gas to lower the temperature of liquid helium bath down to 1.8 K. A 200 W, 1.3 GHz RF system has been indigenously developed for testing of the SCRF cavities. The VTS facility has now been ...