Papers by Roberto Baruffa
Estendibilità Del Potere Fonoisolante DI Serramenti e Altri Componenti Edilizi

Proceedings of the ICA congress, 2019
This paper describes the design principles underlying the Round Robin Test (RRT) carried out amon... more This paper describes the design principles underlying the Round Robin Test (RRT) carried out among the laboratories of the Sound Absorption working group of the Italian Standardization Body (UNI). In recent years, the determination of the measurement uncertainties in the fields of building and room acoustics has attracted increasing attention. In particular, sound absorption in a diffuse sound field might be difficult to determine, especially for very highly absorptive materials. Results coming from different laboratories cannot always be compared, due to differences in the actual sound field found in nominally equivalent facilities. During this RRT, carefully selected samples have been measured in the reverberation rooms of the different laboratories participating in the RRT according to standard ISO 354 in force as well as the newly proposed draft. The procedure will be presented in the paper.

Rivista Italiana di Acustica, 2016
Negli edifici aventi grandi altezze, il vento non costituisce solo una sollecitazione dinamica, m... more Negli edifici aventi grandi altezze, il vento non costituisce solo una sollecitazione dinamica, ma anche una possibile sorgente di rumore sia per l’ambiente interno che per quello esterno. In presenza di elevate velocita d’aria, gli elementi della facciata, spesso in aggetto e con griglie, possono innescare uno o piu dei meccanismi di generazione del rumore aero-dinamico. Nel presente lavoro sono illustrate le modalita di prova e di analisi dei risultati di una estesa campagna metrologica, compiuta in laboratorio, sugli elementi apribili esterni di una facciata a doppia pelle, sottoposti a prova variandone il grado di apertura, l’angolo di incidenza e velocita del flusso d’aria. ------ In buildings having a relevant height, wind is not only a dynamic load, but even a possible noise source both for internal that for external environment. In the presence of air at high speed, facade elements, often with projection components and grills, can trigger one or more generation mechanisms of...

Towards more reliable measurements of sound absorption coefficient in reverberation rooms: An Inter-Laboratory Test
Applied Acoustics, 2020
Abstract The internationally recognized procedure ISO 354:2003 for measuring sound absorption coe... more Abstract The internationally recognized procedure ISO 354:2003 for measuring sound absorption coefficients under diffuse field conditions is now under revision. The main reason for this revision is the limited reproducibility of absorption coefficients measured in different laboratories that may have significant implications spanning from room acoustic design to material selection. A network of Italian laboratories have come together to carry out an Inter-Laboratory Test (ILT) to assess and compare the measurement uncertainties resulting from the application of the current version of ISO 354:2003 and of the new ISO/CD 354:2019. After detailing the methodological aspects, the paper presents the results of the measurements, discussing the compliance of the laboratories to the standard requirements and new qualification tests, and, more importantly, providing a quantitative estimation of their effects on measurement uncertainty and accuracy.

Correlazione tra potere fonoisolante e rumorosità da pioggia pesante in coperture con finitura metallica - Correlation between airborne sound insulation and heavy rain noise on coverings with metallic finishing
Rivista Italiana di Acustica, 2017
Due camere riverberanti sovrapposte, con la possibilita di disporre i campioni di coperture incli... more Due camere riverberanti sovrapposte, con la possibilita di disporre i campioni di coperture inclinati, come nelle condizioni reali di posa, consentono di effettuare, in successione, prove di potere fonoisolante e di livello di intensita sonora di rumore di pioggia pesante. E quindi possibile individuare gli effetti sulle due grandezze acustiche delle differenti tipologie di coibentazione interna oppure del materiale antirombo impiegato. A causa della difficolta di reperire in letteratura tecnica i dati del livello globale di intensita sonora di rumore di pioggia ponderato A, LIA, si e determinata una correlazione tra LIA e l’indice di valutazione del potere fonoisolante RW e la massa per unita di area dei campioni m. ------ Two overlying reverberation rooms, with the possibility to place the roof's sample tilted, as in the real installation conditions, allow to carry out in succession, the tests of sound insulation and of sound intensity level of heavy rain noise. So is possible...
Uploads
Papers by Roberto Baruffa